Product Introduction
ZYMM1-400L covers rated current of 225A, 250A, 315A, 350A and 400A, rated insulation voltage of Ac 800V, rated working voltage of AC 400V, rated impulse withstand voltage of 8000V, Flying arc distance of 100mm.We provide variable choice about the material(copper point, composite point, silver point and full silver point).
Although electricity has become an integral part of our lives, the fact is that it can also be dangerous to human life and property. Electrocution and fire are the two main risks associated with electricity and one cannot afford to be negligent when it comes to insulated equipment. Yuming Electric’s residual case circuit breaker is designed to detect and trip leakage currents, thus ensuring protection against electric shocks caused by indirect contact.
Product Parameter
Model | ZYMM1-400L | ||
Rated current In(A) | 225,250,315,350,400 | ||
Number of poles | 3 | 4 | |
Rated insulation voltage Ui(V) | AC800 | ||
Rated working voltage Ue(V) | AC400 | ||
Rated impulse withstand voltage Uimp(V) | 8000 | ||
Arcing distance(mm) | 100 | ||
Breaking capacity level | M | H | |
Ultimate short-circuit breaking capacity Icu(kA) | AC400V | 70 | 100 |
Operating short-circuit breaking capacity Ics(kA) | AC400V | 50 | 65 |
Rated residual short-circuit switching (breaking) capacity I△m(kA) | 17.5 | 25 | |
Rated residual action current I△m(mA) | Non-delayed type | 100/300/500 | |
Time-delayed type | 100/300/500 | ||
Rated residual non-action current I△no(mA) | 1/2 I△n | ||
Operational performance/times | Electrify | 1000 | |
No electricity | 4000 | ||
Total number of times | 5000 | ||
Residual current protection action time | 5 I△n | ||
Maximum breaking time(S) | Non-delayed type | 0.04 | |
Time-delayed type | 0.25/0.9/1.9 |
Features & Benefits
◆ The RCCB circuit breaker is designed to protect against the dangers of electric shock, electric shock and fire caused by ground faults or faulty wiring.
◆ Provides protection against earth faults and any leakage currents.
FAQ
Q:What is inside RCCB?
A:The RCCB consists of a CBCT (core balancing current transformer), relay operating coil, incoming and outgoing terminals, tripping mechanism, ON/OFF handle and test switch.
Q:How is your quality of products?
A:Our production strictly follows the ISO9001 quality management system.
Product Introduction
ZYMM1-400L covers rated current of 225A, 250A, 315A, 350A and 400A, rated insulation voltage of Ac 800V, rated working voltage of AC 400V, rated impulse withstand voltage of 8000V, Flying arc distance of 100mm.We provide variable choice about the material(copper point, composite point, silver point and full silver point).
Although electricity has become an integral part of our lives, the fact is that it can also be dangerous to human life and property. Electrocution and fire are the two main risks associated with electricity and one cannot afford to be negligent when it comes to insulated equipment. Yuming Electric’s residual case circuit breaker is designed to detect and trip leakage currents, thus ensuring protection against electric shocks caused by indirect contact.
Product Parameter
Model | ZYMM1-400L | ||
Rated current In(A) | 225,250,315,350,400 | ||
Number of poles | 3 | 4 | |
Rated insulation voltage Ui(V) | AC800 | ||
Rated working voltage Ue(V) | AC400 | ||
Rated impulse withstand voltage Uimp(V) | 8000 | ||
Arcing distance(mm) | 100 | ||
Breaking capacity level | M | H | |
Ultimate short-circuit breaking capacity Icu(kA) | AC400V | 70 | 100 |
Operating short-circuit breaking capacity Ics(kA) | AC400V | 50 | 65 |
Rated residual short-circuit switching (breaking) capacity I△m(kA) | 17.5 | 25 | |
Rated residual action current I△m(mA) | Non-delayed type | 100/300/500 | |
Time-delayed type | 100/300/500 | ||
Rated residual non-action current I△no(mA) | 1/2 I△n | ||
Operational performance/times | Electrify | 1000 | |
No electricity | 4000 | ||
Total number of times | 5000 | ||
Residual current protection action time | 5 I△n | ||
Maximum breaking time(S) | Non-delayed type | 0.04 | |
Time-delayed type | 0.25/0.9/1.9 |
Features & Benefits
◆ The RCCB circuit breaker is designed to protect against the dangers of electric shock, electric shock and fire caused by ground faults or faulty wiring.
◆ Provides protection against earth faults and any leakage currents.
FAQ
Q:What is inside RCCB?
A:The RCCB consists of a CBCT (core balancing current transformer), relay operating coil, incoming and outgoing terminals, tripping mechanism, ON/OFF handle and test switch.
Q:How is your quality of products?
A:Our production strictly follows the ISO9001 quality management system.