Product Introduction
Designed by Yuming Electric for electrical and mechanical OEMs, these proven designs combine the latest innovations with high reliability.
Product Parameter
Model | ZYMM1-125M | |||||
Number of poles | 3 | 2 | 4 | |||
Rated current In(A) | 10,16,20,32,40,50,63,80,100,125 | |||||
Rated insulation voltage(V) | 800 | |||||
Rated impulse withstand voltage(V) | 8000 | |||||
Rated working voltage(V) | AC 400/690 | |||||
Breaking capacity class | L | M | H | L | ||
Ultimate short circuit breaking capacity Ics(kA) | 400V | 35 | 50 | 85 | 35 | |
690V | 20 | |||||
Operating short circuit breaking capacity Icu(kA) | 400V | 22 | 35 | 50 | 22 | |
690V | 10 | |||||
Arcing distance(mm) | 50 | |||||
Number of operation cycles/times | Per hour | 120 | ||||
Electrify | 3000 | |||||
No electricity | 7000 | |||||
Power dissipation(W) | Fixed | 35 | 40 | 40 | 26 | 63 |
Plug-in | 40 | 50 | 50 |
Features
◆ The advanced tripping device function offers a wide range of adjustment for maximum flexibility.
◆ Custom designed tripping devices protect the generator circuit from destructive current levels.
◆ The compact design frees up panel space.
FAQ
Q:What is difference between MCCB and MCB?
A:The MCB is mainly used for low circuit currents, while the MCCB is used for heavy current circuits. the MCB is used for low energy requirements (domestic), while the MCCB is used in areas with high energy requirements (large industrial).
Q:Do you test all your goods before delivery?
A:We would take strict test of quality and performance in specialized quality testing room before delivery.
Product Introduction
Designed by Yuming Electric for electrical and mechanical OEMs, these proven designs combine the latest innovations with high reliability.
Product Parameter
Model | ZYMM1-125M | |||||
Number of poles | 3 | 2 | 4 | |||
Rated current In(A) | 10,16,20,32,40,50,63,80,100,125 | |||||
Rated insulation voltage(V) | 800 | |||||
Rated impulse withstand voltage(V) | 8000 | |||||
Rated working voltage(V) | AC 400/690 | |||||
Breaking capacity class | L | M | H | L | ||
Ultimate short circuit breaking capacity Ics(kA) | 400V | 35 | 50 | 85 | 35 | |
690V | 20 | |||||
Operating short circuit breaking capacity Icu(kA) | 400V | 22 | 35 | 50 | 22 | |
690V | 10 | |||||
Arcing distance(mm) | 50 | |||||
Number of operation cycles/times | Per hour | 120 | ||||
Electrify | 3000 | |||||
No electricity | 7000 | |||||
Power dissipation(W) | Fixed | 35 | 40 | 40 | 26 | 63 |
Plug-in | 40 | 50 | 50 |
Features
◆ The advanced tripping device function offers a wide range of adjustment for maximum flexibility.
◆ Custom designed tripping devices protect the generator circuit from destructive current levels.
◆ The compact design frees up panel space.
FAQ
Q:What is difference between MCCB and MCB?
A:The MCB is mainly used for low circuit currents, while the MCCB is used for heavy current circuits. the MCB is used for low energy requirements (domestic), while the MCCB is used in areas with high energy requirements (large industrial).
Q:Do you test all your goods before delivery?
A:We would take strict test of quality and performance in specialized quality testing room before delivery.